Review




Structured Review

ActiGraph llc tri-axial accelerometer gt9x link imu
Tri Axial Accelerometer Gt9x Link Imu, supplied by ActiGraph llc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/tri-axial accelerometer gt9x link imu/product/ActiGraph llc
Average 90 stars, based on 1 article reviews
tri-axial accelerometer gt9x link imu - by Bioz Stars, 2026-06
90/100 stars

Images



Similar Products

90
ActiGraph llc tri-axial accelerometer gt9x link imu
Tri Axial Accelerometer Gt9x Link Imu, supplied by ActiGraph llc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/tri-axial accelerometer gt9x link imu/product/ActiGraph llc
Average 90 stars, based on 1 article reviews
tri-axial accelerometer gt9x link imu - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
ActiGraph llc imu gt9x link
Imu Gt9x Link, supplied by ActiGraph llc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/imu gt9x link/product/ActiGraph llc
Average 90 stars, based on 1 article reviews
imu gt9x link - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
ActiGraph llc imu sensor actigraph gt9x link
Imu Sensor Actigraph Gt9x Link, supplied by ActiGraph llc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/imu sensor actigraph gt9x link/product/ActiGraph llc
Average 90 stars, based on 1 article reviews
imu sensor actigraph gt9x link - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
ActiGraph llc gt9x link imus
Clinical population studies
Gt9x Link Imus, supplied by ActiGraph llc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/gt9x link imus/product/ActiGraph llc
Average 90 stars, based on 1 article reviews
gt9x link imus - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
ActiGraph llc imu sensors actigraph gt9x links
Clinical population studies
Imu Sensors Actigraph Gt9x Links, supplied by ActiGraph llc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/imu sensors actigraph gt9x links/product/ActiGraph llc
Average 90 stars, based on 1 article reviews
imu sensors actigraph gt9x links - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
ActiGraph llc gt9x imu sensor
Clinical population studies
Gt9x Imu Sensor, supplied by ActiGraph llc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/gt9x imu sensor/product/ActiGraph llc
Average 90 stars, based on 1 article reviews
gt9x imu sensor - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
ActiGraph llc imus gt9x links
Clinical population studies
Imus Gt9x Links, supplied by ActiGraph llc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/imus gt9x links/product/ActiGraph llc
Average 90 stars, based on 1 article reviews
imus gt9x links - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
ActiGraph llc gt9x link inertial measurement units (imus)
Clinical population studies
Gt9x Link Inertial Measurement Units (Imus), supplied by ActiGraph llc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/gt9x link inertial measurement units (imus)/product/ActiGraph llc
Average 90 stars, based on 1 article reviews
gt9x link inertial measurement units (imus) - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

Image Search Results


Clinical population studies

Journal: Journal of NeuroEngineering and Rehabilitation

Article Title: Applications of wearable sensors in upper extremity MSK conditions: a scoping review

doi: 10.1186/s12984-023-01274-w

Figure Lengend Snippet: Clinical population studies

Article Snippet: (8) Schall et al. 2021 [ ] , 35 Subjects [18 manufacturing cyclic workers and 17 non-cyclic workers] , Randomized clinical trial , (1) Comparing mean levels of full-shift exposure summary metrics based on both posture and movement speed between manufacturing cyclic and non-cyclic workers (2) Exploring the patterns of between- and within-worker exposure variance and between-minute (within-shift) exposure level and variation within each group , Upper arms and dominant wrist , (1) 3 ActiGraph GT9X Link IMUs (ActiGraph, USA, sampling frequency = 100 Hz) fixed with elastic hook-and-loop fastener straps using hypoallergenic cohesive bandages , (1) Upper arms posture or angles (°), and relative time spent at neutral and extreme states (%) (2) Angular movement speed (°/s) and relative time spent at low-speed and high-speed states (%) (3) Relative time spent at 3 states of low speed, neutral, and low speed-neutral of rest/recovery exposure (%) , ActiGraph Software , ×/✓.

Techniques: Software, Control, Activation Assay, Sampling, Activity Assay, Injection, Comparison, Adhesive, Biomarker Discovery, Functional Assay, Plasmid Preparation, Battery

Workers’ population studies

Journal: Journal of NeuroEngineering and Rehabilitation

Article Title: Applications of wearable sensors in upper extremity MSK conditions: a scoping review

doi: 10.1186/s12984-023-01274-w

Figure Lengend Snippet: Workers’ population studies

Article Snippet: (8) Schall et al. 2021 [ ] , 35 Subjects [18 manufacturing cyclic workers and 17 non-cyclic workers] , Randomized clinical trial , (1) Comparing mean levels of full-shift exposure summary metrics based on both posture and movement speed between manufacturing cyclic and non-cyclic workers (2) Exploring the patterns of between- and within-worker exposure variance and between-minute (within-shift) exposure level and variation within each group , Upper arms and dominant wrist , (1) 3 ActiGraph GT9X Link IMUs (ActiGraph, USA, sampling frequency = 100 Hz) fixed with elastic hook-and-loop fastener straps using hypoallergenic cohesive bandages , (1) Upper arms posture or angles (°), and relative time spent at neutral and extreme states (%) (2) Angular movement speed (°/s) and relative time spent at low-speed and high-speed states (%) (3) Relative time spent at 3 states of low speed, neutral, and low speed-neutral of rest/recovery exposure (%) , ActiGraph Software , ×/✓.

Techniques: Software, Sampling, Marker, Control, Modification, Adhesive, Activity Assay, Comparison, Biomarker Discovery, Functional Assay, Activation Assay, Imaging

General wearable design/performance studies

Journal: Journal of NeuroEngineering and Rehabilitation

Article Title: Applications of wearable sensors in upper extremity MSK conditions: a scoping review

doi: 10.1186/s12984-023-01274-w

Figure Lengend Snippet: General wearable design/performance studies

Article Snippet: (8) Schall et al. 2021 [ ] , 35 Subjects [18 manufacturing cyclic workers and 17 non-cyclic workers] , Randomized clinical trial , (1) Comparing mean levels of full-shift exposure summary metrics based on both posture and movement speed between manufacturing cyclic and non-cyclic workers (2) Exploring the patterns of between- and within-worker exposure variance and between-minute (within-shift) exposure level and variation within each group , Upper arms and dominant wrist , (1) 3 ActiGraph GT9X Link IMUs (ActiGraph, USA, sampling frequency = 100 Hz) fixed with elastic hook-and-loop fastener straps using hypoallergenic cohesive bandages , (1) Upper arms posture or angles (°), and relative time spent at neutral and extreme states (%) (2) Angular movement speed (°/s) and relative time spent at low-speed and high-speed states (%) (3) Relative time spent at 3 states of low speed, neutral, and low speed-neutral of rest/recovery exposure (%) , ActiGraph Software , ×/✓.

Techniques: Software, Sampling, Activation Assay, Concentration Assay, Activity Assay, MicroChIP Assay, Biomarker Discovery

Number of different types of sensors used in all studies; Examples of others include smartwatches, self-developed systems, LED, and non-IMUs

Journal: Journal of NeuroEngineering and Rehabilitation

Article Title: Applications of wearable sensors in upper extremity MSK conditions: a scoping review

doi: 10.1186/s12984-023-01274-w

Figure Lengend Snippet: Number of different types of sensors used in all studies; Examples of others include smartwatches, self-developed systems, LED, and non-IMUs

Article Snippet: (8) Schall et al. 2021 [ ] , 35 Subjects [18 manufacturing cyclic workers and 17 non-cyclic workers] , Randomized clinical trial , (1) Comparing mean levels of full-shift exposure summary metrics based on both posture and movement speed between manufacturing cyclic and non-cyclic workers (2) Exploring the patterns of between- and within-worker exposure variance and between-minute (within-shift) exposure level and variation within each group , Upper arms and dominant wrist , (1) 3 ActiGraph GT9X Link IMUs (ActiGraph, USA, sampling frequency = 100 Hz) fixed with elastic hook-and-loop fastener straps using hypoallergenic cohesive bandages , (1) Upper arms posture or angles (°), and relative time spent at neutral and extreme states (%) (2) Angular movement speed (°/s) and relative time spent at low-speed and high-speed states (%) (3) Relative time spent at 3 states of low speed, neutral, and low speed-neutral of rest/recovery exposure (%) , ActiGraph Software , ×/✓.

Techniques:

Clinical population studies

Journal: Journal of NeuroEngineering and Rehabilitation

Article Title: Applications of wearable sensors in upper extremity MSK conditions: a scoping review

doi: 10.1186/s12984-023-01274-w

Figure Lengend Snippet: Clinical population studies

Article Snippet: (12) Zhang et al. 2022 [ ] , 30 Manufacturing workers (2 cyclic/ non-cyclic groups of 15 workers) , Cross-sectional case control , (1) Quantification of self-reported daily discomfort, distraction and burden caused by putting on wearable inertial sensors in manufacturing workers (2) Evaluating contribution level of different personal and work characteristics on the discomfort, distraction, and burden ratings , Upper arms, and dominant wrist , (1) 3 IMU sensors of ActiGraph GT9X Links (ActiGraph, USA) fixated with elastic hook and loop fastener straps , (1) Upper arm elevation angle (°), and the magnitude of the elevation speeds (°/s) , ActiLife , ✓/×.

Techniques: Software, Activation Assay, Sampling, Activity Assay, Injection, Comparison, Adhesive, Functional Assay, Plasmid Preparation, Battery

Workers’ population studies

Journal: Journal of NeuroEngineering and Rehabilitation

Article Title: Applications of wearable sensors in upper extremity MSK conditions: a scoping review

doi: 10.1186/s12984-023-01274-w

Figure Lengend Snippet: Workers’ population studies

Article Snippet: (12) Zhang et al. 2022 [ ] , 30 Manufacturing workers (2 cyclic/ non-cyclic groups of 15 workers) , Cross-sectional case control , (1) Quantification of self-reported daily discomfort, distraction and burden caused by putting on wearable inertial sensors in manufacturing workers (2) Evaluating contribution level of different personal and work characteristics on the discomfort, distraction, and burden ratings , Upper arms, and dominant wrist , (1) 3 IMU sensors of ActiGraph GT9X Links (ActiGraph, USA) fixated with elastic hook and loop fastener straps , (1) Upper arm elevation angle (°), and the magnitude of the elevation speeds (°/s) , ActiLife , ✓/×.

Techniques: Software, Sampling, Marker, Modification, Adhesive, Activity Assay, Comparison, Functional Assay, Activation Assay, Imaging

Clinical population studies

Journal: Journal of NeuroEngineering and Rehabilitation

Article Title: Applications of wearable sensors in upper extremity MSK conditions: a scoping review

doi: 10.1186/s12984-023-01274-w

Figure Lengend Snippet: Clinical population studies

Article Snippet: (20) Perraudin et al. 2018 [ ] , Intervention: 30 patients with osteoarthritis, rheumatoid arthritis, or psoriatic arthritis Control: 15 healthy subjects , Cross-sectional case control , (1) The feasibility of performing unsupervised, correct, and consistent sit to stand tests at home (2) Finding a model that can that demonstrate the relationship of the tests duration obtained from sensors to pain and stiffness , Wrist , 1 ActiGraph GT9X IMU sensor (ActiGraph Inc., USA, sampling frequency = 30 Hz) mounted on a wristband , (1) The 3-axis accelerometer data (g), and its spherical coordinates (norm vector, azimuth in degrees, elevation in degrees) (2) The duration of the 5 × STS tests (s) (3) Adherence to the tests (%) , Self-developed smartphone app , ✓/×/×.

Techniques: Software, Activation Assay, Sampling, Activity Assay, Injection, Comparison, Adhesive, Functional Assay, Plasmid Preparation, Battery

Workers’ population studies

Journal: Journal of NeuroEngineering and Rehabilitation

Article Title: Applications of wearable sensors in upper extremity MSK conditions: a scoping review

doi: 10.1186/s12984-023-01274-w

Figure Lengend Snippet: Workers’ population studies

Article Snippet: (20) Perraudin et al. 2018 [ ] , Intervention: 30 patients with osteoarthritis, rheumatoid arthritis, or psoriatic arthritis Control: 15 healthy subjects , Cross-sectional case control , (1) The feasibility of performing unsupervised, correct, and consistent sit to stand tests at home (2) Finding a model that can that demonstrate the relationship of the tests duration obtained from sensors to pain and stiffness , Wrist , 1 ActiGraph GT9X IMU sensor (ActiGraph Inc., USA, sampling frequency = 30 Hz) mounted on a wristband , (1) The 3-axis accelerometer data (g), and its spherical coordinates (norm vector, azimuth in degrees, elevation in degrees) (2) The duration of the 5 × STS tests (s) (3) Adherence to the tests (%) , Self-developed smartphone app , ✓/×/×.

Techniques: Software, Sampling, Marker, Modification, Adhesive, Activity Assay, Comparison, Functional Assay, Activation Assay, Imaging